When you are short of time, TOPO cloning removes two whole steps: Thermo Fisher's system skips the restriction digest and the ligation, and the joining reaction takes five minutes at room temperature with no ATP.
It also has a high per-reaction cost compared with other cloning methods, and you cannot make the reagents yourself.
This guide explains how the enzyme works, which of the three systems suits which PCR product, and where the premium is actually worth paying.
At a glance
- Mechanism: One enzyme, topoisomerase I, cuts and rejoins the DNA. No ligase and no ATP.
- Three systems: TA for Taq products, Zero Blunt for high-fidelity products, Directional for expression constructs.
- Watch for: A polymerase mix that does not leave the ends your kit expects, and salt carried over from the PCR.
The biology of topoisomerase I
Most cloning needs one enzyme to cut and another to join. TOPO cloning uses a single enzyme from vaccinia virus: topoisomerase I.
In nature, this enzyme relieves supercoiling in DNA. It binds a short recognition sequence, CCCTT, and cuts one strand of the backbone. A tyrosine in its active site attacks the DNA and forms a covalent bond between the enzyme and the 3' phosphate of the cut strand.
This is what makes the method work: the energy of the original phosphodiester bond is not released; it is stored in the new enzyme-to-DNA bond. The vector sits open, charged and ready to react, with no outside energy needed.
When a compatible PCR product arrives, the free 5'-hydroxyl of the insert attacks that bond. The enzyme is released, the insert is joined, and the plasmid closes.
Kits supply the vector already linearized with topoisomerase attached at both ends. All you add is your product. There is nothing to prepare, which is both the appeal and the reason it costs what it does.
The three TOPO systems
Each system is matched to a particular kind of DNA end. Pairing the wrong vector with your polymerase is a common reason a TOPO reaction fails, and it fails completely rather than inefficiently.
| System | Polymerase | Ends | Directional |
|---|---|---|---|
| TOPO TA | Standard Taq | 3' A overhangs | No |
| Zero Blunt TOPO | High-fidelity | Blunt | No |
| Directional TOPO | High-fidelity | Blunt, with CACC tail | Yes |
TOPO TA is built for products made with standard Taq, which adds a single adenine to the 3' ends. The vector carries matching T overhangs. Use it for archiving fragments and sequencing templates. The insert can go in either orientation.
Zero Blunt TOPO is for products from proofreading polymerases such as Q5 or Phusion, which leave blunt ends. Because blunt joining is less efficient, these vectors carry the ccdB gene as a negative selection marker. CcdB poisons DNA gyrase, so a vector that closes without an insert kills its host cell, and most of the empty-vector background disappears before you see it.
Directional TOPO solves the orientation problem. The vector carries a four-base single-stranded GTGG overhang, and you add the complementary CACC sequence to the 5' end of your forward primer. The insert can then only go in one way round, which is what makes it practical to put an open reading frame straight into an expression vector with no intermediate construct.
Choose the system before you amplify. Directional TOPO needs the CACC designed into the primer, so it is not a decision you can make after the PCR.
Cost and when to use it
The expense is in the pre-charged vectors. You cannot make them or propagate them yourself, so every reaction consumes a kit component, and the cost per clone stays flat however many you do.
For routine archiving of short PCR products, blunt-end cloning or laboratory-prepared TA vectors cost a fraction as much and work perfectly well. You spend an extra day and save most of the money.
Save the TOPO premium for the cases where time is genuinely the limiting factor: high-throughput archiving where the handling time per sample dominates the work, or getting a gene directly into a proprietary expression vector without building an intermediate.
It is also worth being clear about what the five minutes buys. The reaction is fast; the experiment is not. DNA preparation, transformation, overnight growth, colony screening and sequencing take as long as they ever do.
Plan it first
A five-minute reaction does not remove the need to plan, and a fast assembly is no use if the reading frame is wrong.
This applies above all to Directional TOPO. If you put the CACC on the reverse primer by mistake, your insert goes in backwards in the one system you chose specifically to control orientation.
Build your construct in Photo51 before you order primers. Check the reading frame, confirm the CACC is on the forward primer, and design the screening primers you will use afterwards. For the non-directional kits, build both orientations so you have primers ready to tell them apart.
Troubleshooting
Bare plates with Zero Blunt TOPO
Symptom: You used the Zero Blunt kit and the plates are completely empty.
Cause: Your product was not blunt. Some commercial mixes, particularly long-range amplification mixes, contain Taq alongside a proofreading enzyme and leave A overhangs.
Fix: Check the composition of your polymerase mix rather than its name. If the ends carry an A overhang, the blunt vector cannot accept them and closes empty, and the ccdB gene then kills the cells that took it up. So a bare plate here is the selection working correctly. Either switch to a true blunt product or use the TA kit instead.
Two or three colonies, all empty
Symptom: You followed the five-minute protocol and got a handful of colonies, none with an insert.
Cause: Salt carried over from the PCR, or too much unpurified product diluting the supplied reaction buffer.
Fix: TOPO reactions are sensitive to salt. Purify the PCR product first, and keep the insert to 1 or 2 µL in a 6 µL reaction. Adding 4 µL of unpurified product dilutes the buffer enough to stall the reaction, which is easy to do when the product is faint and the instinct is to add more.
The insert went in backwards with a directional kit
Symptom: You used Directional TOPO and half or more of the clones are inverted.
Cause: The CACC is not where it should be. Most often it was added to the reverse primer, or to both.
Fix: Check the primer sequences against the design. The CACC belongs on the 5' end of the forward primer only. There is no bench fix for this, so the clones you have are the clones you have, and you will need new primers.